Page - 60/73 AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual
13.6 Description of the battery charge detection setting
The Battery Charge detection uses two setting that specify the Full Charge
Voltage Level (100%) and the Discharge Voltage Level (10%). These two
settings are the ADJUSTMENT#01 and the ADJUSTMENT#02 (see 12.4.2.14
and 12.4.2.15). It is possible to adapt the Battery Charge Detection to your
specific battery, by changing the above two settings (e.g. if the Battery
Discharged Detection occurs when the battery is not totally discarghed, it is
necessary to reduce the ADJUSTMENT #02 setting as indicated in the Figure
13–3 below).
Figure 13–3